Section 49 – Signals, Lighting and Electrical Systems
12/1/03
49.2
associated equipment. In particular, the record drawings shall accurately depict the location
and depth of conduits, location of standards, pull boxes, wiring changes, and all applicable
manufacturer’s operation and maintenance information.
49-1.05 Ordering of Signal and Lighting Equipment
The Contractor shall place the order for long lead-time signal and lighting equipment not
provided by the Agency within five (5) days of receiving notice that they have been awarded the
Contract. The Contractor shall submit a copy of the equipment order to the Agency. Liquidated
damages, as set forth in Section 8-10, “Liquidated Damages for Delay”, of these Specifications,
shall apply in case of failure to comply. No extension of time will be allowed for delay in delivery
of traffic signal poles, street light standards, luminaries, or traffic signal equipment. The Agency
hereby guarantees payment for long lead-time equipment ordered prior to execution of the
Contract.
The Contractor shall furnish the Agency with a statement from the vendor(s) that the order
for the electrical material required for the contract has been received and accepted by said
vendor(s). Said statement shall be furnished within ten (10) days after receiving notice that the
Contract has been executed for the Agency. Said statement shall give the date that the
electrical equipment will be shipped.
49-1.06 Maintaining Existing and Temporary Electrical Systems
Maintaining existing and temporary electrical systems shall conform to Section 86-1.06,
“Maintaining Existing and Temporary Electrical Systems”, of the State Specifications, except
that paragraphs 11, 12, and 13 shall not apply.
Existing electrical systems, including traffic signals, traffic signal vehicle and pedestrian
detection facilities, traffic signal communication and monitoring facilities, street lighting facilities,
flashing beacons and sign illumination facilities, or approved temporary replacements thereof,
shall be kept in effective operation for the benefit of the traveling public during the progress of
the Work, except when shutdown is permitted to allow for alterations or final removal of the
systems.
The Contractor shall notify the Agency at least two (2) Working Days prior to performing any
work on existing systems, including any work that may take vehicle detectors out of service or
may reroute traffic off of existing vehicle detectors.
The Contractor shall notify the Agency at least two (2) Working Days prior to any operational
shutdown of traffic signals, street lighting or other electrical systems or facilities.
Traffic control to direct traffic during the shutdown of a traffic signal system shall be provided
by the Contractor at the Contractor’s expense. The Contractor shall submit a traffic control plan
to the Agency for review and approval a minimum of five (5) Working Days prior to a shutdown
of a traffic signal. Traffic signal shutdowns shall be limited to Monday through Thursday,
excluding holidays, from 9:00 a.m. to 3:00 p.m., or as specified in the Special Provisions.
Where a facility requires continuous lighting, the shutdown time shall be limited to one-half
(1/2) hour as scheduled by the Agency, unless otherwise specified in the Special Provisions or
permitted by the Agency. The shutdown of lighting systems shall not interfere with the regular
lighting schedule, unless otherwise permitted by the Agency.



This Section: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Sections
: 1 2 3 4 5 6 7 8 9

Remodeling a home can be costly and frustrating, especially in decor of kitchen cabinets, veneer, bathrooms, vinyl siding, arts / crafts, patio enclosures, replacement windows doors, furniture, swimming pools spa, home security, or other architecture areas. Free Add Site 1, 2, 3, 4, 5, 6, 7
 

ADT Home Security - Replacement Windows - Home Improvement Ideas - Vinyl Siding Prices - Shopping - Bat Pest Control
Swimming Pools / Spa - Kitchen Cabinet Remodeling - Patio Enclosures - Site Map - Add URL Real Estate

Copyright © 2004 - 2008 Sunrooms and Spas by Site-Found

Art / Decor Business / Companies Computers / Accessories Education / Schools Entertainment / Books Health / Environment Home and Garden Home Improvement / Decorating Home Sales / Real Estate Life / Homes Literature / Classics Miscellaneous Recreation / Sports Science / Technology Shopping / Gifts Society / Family Websites / Logos Favorites Add URL 2 3 4 5 6