Section 38 – Sewer and Storm Drain Construction
12/1/03
38.18
38-10.03.B Storm Drain
When indicated in the Contract, or when inferior products or construction methods are used
or visual inspection by television or lamping indicates a potential for excessive deflection, the
following test method shall be used:
Where PVC or HDPE pipe are installed as drain pipe, a deflection test shall be made by
the Contractor upon completion and acceptance of all backfill operations and prior to
placement of the finished surface, if any. Deflection testing shall be conducted no
sooner than thirty (30) Calendar Days following completion and acceptance of all backfill
operations, unless otherwise approved by the Agency.
The deflection testing shall be witnessed by the Inspector and shall be conducted by the
Contractor at the Contractor's expense. Unless otherwise shown on the Plans or in the Special
Provisions, one-hundred percent (100%) of all mainline PVC and HDPE drain pipe installed
shall be deflection tested for excessive vertical deflection using a pre-sized, rigid mandrel or
"Go-No-Go" device approved by the Agency. The mandrel size shall be clearly labeled and
shall be sized so as to provide a diameter of at least 92.5% of the "Base Internal Diameter" per
ASTM D 3034 for PVC and ASTM F 894 for HDPE. Base inside diameters for larger diameters
of PVC pipe may be found in ASTM F 679.
The Contractor shall remove, replace, and retest any pipe section through which the
mandrel is unable to pass. The use of any rerounding device or similar method to correct or
reduce over deflection will not be permitted. Re-tests for deflections shall be made at the
Contractor’s expense.
38-10.04 Television Inspection (TVI)
A closed circuit television inspection (TVI) shall be conducted prior to new sewer or storm
drain pipeline acceptance and prior to and after completion of pipeline rehabilitation projects.
The TVI shall document and verify:
1. The overall condition of the pipeline,
2. The location of service taps,
3. Line and grade,
4. Cleanliness, and
5. That post-installation inspection per the Contract has taken place.
In addition, TVI documentation shall indicate:
1. Consistent use of standard forms and codes
2. Uniform compliance with setup and inspection procedures
3. Quality pictures and audible records
4. Suitable camera speed, lighting, and panning
5. Accuracy when recording file names and electronic data.
The TVI shall be documented in an electronic report (TVI Report) and digital video recording
as specified herein. Contractors shall comply with the County of Sacramento Department of
Water Quality Television Inspection Manual Draft 2001, or most current edition (Television
Inspection Manual), available at the Water Quality Department Customer Service office at
10545 Armstrong Ave., Suite 101, Mather, CA. 95655, phone (916) 876-6100. The Television
Inspection Manual contains the requirements for collection and documentation of TVI data. It is
the Contractor’s responsibility to verify that electronic documentation is in the latest, most up-to-
date format required by the Agency. TVI of new construction shall be performed after all
required testing specified in the Contract and/or this Section is satisfactorily completed. The
cleaning of sanitary sewers or storm drains shall be performed prior to the TVI in a separate
operation, unless otherwise specified. Unless otherwise shown or specified in the Contract, the
Contractor shall perform a TVI on all sewers between manholes or manhole to flusher
branch/stub or to existing manholes, as necessary, to video a complete segment, all storm
drains between manholes or to existing manholes, as necessary, to video a complete segment,



This Section: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Sections
: 1 2 3 4 5 6 7 8 9

Remodeling a home can be costly and frustrating, especially in decor of kitchen cabinets, veneer, bathrooms, vinyl siding, arts / crafts, patio enclosures, replacement windows doors, furniture, swimming pools spa, home security, or other architecture areas. Free Add Site 1, 2, 3, 4, 5, 6, 7
 

ADT Home Security - Replacement Windows - Home Improvement Ideas - Vinyl Siding Prices - Shopping - Bat Pest Control
Swimming Pools / Spa - Kitchen Cabinet Remodeling - Patio Enclosures - Site Map - Add URL Real Estate

Copyright © 2004 - 2008 Swimming Pools by Site-Found

Art / Decor Business / Companies Computers / Accessories Education / Schools Entertainment / Books Health / Environment Home and Garden Home Improvement / Decorating Home Sales / Real Estate Life / Homes Literature / Classics Miscellaneous Recreation / Sports Science / Technology Shopping / Gifts Society / Family Websites / Logos Favorites Add URL 2 3 4 5 6